Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker Status Priority Subject Assignee Updated Target version Estimated time % Done
74 Demo VM Evolution Nouveau Normal PhpLdapAdmin François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
72 Demo VM Evolution Nouveau Normal PhpMyAdmin François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
77 Demo VM Evolution Nouveau Normal PhpPgAdmin François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
85 Demo VM Evolution Nouveau Normal Port JETL samples from 5.2.1 to 5.4.1 François Cerbelle 01/25/2014 02:41 PM Demo VM - Later 4:00

Actions
76 Demo VM Evolution Nouveau Normal PostgreSQL::JDBC François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
75 Demo VM Evolution Nouveau Normal PostgreSQL::server François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
45 Demo VM Anomalie Nouveau Normal Resolve the JAR conflict between Liferay and JasperReports Server François Cerbelle 01/25/2014 02:42 PM Demo VM - Later

Actions
79 Demo VM Evolution Nouveau Normal RockMongo François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
115 Demo VM Anomalie Nouveau Normal Sameer's Foodmart2012 samples OLAP view are broken François Cerbelle 04/09/2014 06:00 PM Demo VM - Later 3:00

Actions
120 Demo VM Evolution Nouveau Normal System status and halt in header François Cerbelle 01/25/2014 02:41 PM Demo VM - Later 2:00

Actions
129 Demo VM Anomalie Résolu Normal Tabbed home page broken in 5.6 François Cerbelle 06/27/2014 06:05 PM Demo VM - Later

Actions
82 Demo VM Evolution Nouveau Normal Tomcat6 François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
80 Demo VM Evolution Nouveau Normal Web pages and auto-doc framework François Cerbelle 04/09/2014 06:01 PM Demo VM - Later

Actions
97 Demo VM Evolution Nouveau Normal Web Patch : Audit François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
98 Demo VM Evolution Nouveau Normal Web Patch : CanViewQuery François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
101 Demo VM Evolution Nouveau Normal Web Patch : CAS SSO activation François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
94 Demo VM Evolution Nouveau Normal Web Patch : ESAPI security François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
96 Demo VM Evolution Nouveau Normal Web Patch : Heartbeat François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
95 Demo VM Evolution Nouveau Normal Web Patch : Monitoring François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
99 Demo VM Evolution Nouveau Normal Web Patch : Persistent snapshots François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
100 Demo VM Evolution Nouveau Normal Web Patch : Schedule snapshot refresh François Cerbelle 04/09/2014 06:02 PM Demo VM - Later

Actions
209 FC005-ElectronicLoad Anomalie Résolu Normal Add a low pass filter on 24V input 07/04/2020 12:06 PM FC005-ElectronicLoad - 1.1

Actions
216 FC005-ElectronicLoad Anomalie Résolu Normal Add a second fan to balance current between -12/+12 and for better heat protection 07/07/2020 12:11 AM FC005-ElectronicLoad - 1.1 2:00

Actions
192 FC005-ElectronicLoad Evolution Nouveau Normal Add debouncing to the rotary encoder (selector and switch) and trigger using 74LS14 and 74LS74 07/06/2020 02:53 PM FC005-ElectronicLoad - 1.1 2:00

Actions
211 FC005-ElectronicLoad Evolution Résolu Normal Add debug solder bridges to isolate each pin of each connector 07/14/2020 07:12 PM FC005-ElectronicLoad - 1.1 1:00

Actions
212 FC005-ElectronicLoad Evolution Résolu Normal Add debug test points for I2C 07/04/2020 11:43 AM FC005-ElectronicLoad - 1.1

Actions
210 FC005-ElectronicLoad Anomalie Résolu Normal Add low pass filters on -12V, +12V and +5V 07/03/2020 11:42 PM FC005-ElectronicLoad - 1.1

Actions
208 FC005-ElectronicLoad Anomalie Résolu Normal Add trimmer to tune the feedback gain to x66 07/04/2020 11:40 AM FC005-ElectronicLoad - 1.1

Actions
203 FC005-ElectronicLoad Evolution Résolu Normal Choose a better Crystal for Y1 07/04/2020 03:18 PM FC005-ElectronicLoad - 1.1

Actions
235 FC005-ElectronicLoad Anomalie Résolu Normal Choose and add an OpAmp as buffer / impedance adaptor between INT-TEMP and ADC 07/14/2020 12:23 AM FC005-ElectronicLoad - 1.1 1:00

Actions
231 FC005-ElectronicLoad Anomalie Nouveau Normal Choose and add an OpAmp as buffer / impedance adaptor between INT-TEMP/EXT-TEMP and ADC with convertion to 0-5V range for ADC 07/14/2020 11:59 AM FC005-ElectronicLoad - 1.1 1:00

Actions
251 FC005-ElectronicLoad Anomalie Résolu Haut Cleanup schema 07/15/2020 04:54 PM FC005-ElectronicLoad - 1.1 2:00

Actions
217 FC005-ElectronicLoad Anomalie Résolu Normal Compensate current drawn by LM7805 on GND/+12V only 07/04/2020 12:06 AM FC005-ElectronicLoad - 1.1

Actions
229 FC005-ElectronicLoad Evolution Résolu Normal Connect LM7805 to -12/+12 instead of GND/+12 07/06/2020 01:41 PM FC005-ElectronicLoad - 1.1 1:00

Actions
201 FC005-ElectronicLoad Anomalie Résolu Normal Connect the reset button on U10 reset pin 07/03/2020 06:44 PM FC005-ElectronicLoad - 1.1

Actions
230 FC005-ElectronicLoad Evolution Résolu Normal Convert the whole resistor block use only -12/+12 (no 5V dependency anymore) 07/14/2020 12:14 AM FC005-ElectronicLoad - 1.1 3:00

Actions
214 FC005-ElectronicLoad Evolution Résolu Normal Convert the whole security block to use only -12/+12 (no GND/5V anymore) 07/07/2020 12:15 AM FC005-ElectronicLoad - 1.1

Actions
206 FC005-ElectronicLoad Anomalie Résolu Normal DAC output is always 0V 07/03/2020 06:44 PM FC005-ElectronicLoad - 1.1

Actions
202 FC005-ElectronicLoad Anomalie Résolu Normal Fan not starting 07/03/2020 06:44 PM FC005-ElectronicLoad - 1.1

Actions
267 FC005-ElectronicLoad Anomalie Nouveau Normal Fix C15/C16 footprints 10/06/2020 04:03 PM FC005-ElectronicLoad - 1.1 0:15

Actions
268 FC005-ElectronicLoad Anomalie Nouveau Haut Fix connection C25/1 with track +5V !!! 10/06/2020 07:49 PM FC005-ElectronicLoad - 1.1 0:15

Actions
200 FC005-ElectronicLoad Evolution Résolu Bas Fix L1 inductance footprint 07/04/2020 11:39 AM FC005-ElectronicLoad - 1.1

Actions
199 FC005-ElectronicLoad Anomalie Résolu Normal Fix status LEDs current limiting resistors 07/03/2020 06:44 PM FC005-ElectronicLoad - 1.1

Actions
223 FC005-ElectronicLoad Anomalie Résolu Normal fix Y1 crystal footprint 07/04/2020 01:27 PM FC005-ElectronicLoad - 1.1 1:00

Actions
222 FC005-ElectronicLoad Evolution Résolu Haut Include firmware source code in the repository 07/04/2020 11:41 AM FC005-ElectronicLoad - 1.1

Actions
256 FC005-ElectronicLoad Anomalie Résolu Normal Investigate current limiting and thermal runaway in MOSFET with transistors and resistors 07/23/2020 11:51 PM FC005-ElectronicLoad - 1.1

Actions
226 FC005-ElectronicLoad Evolution Résolu Normal LCD connector PCB silkscreen info 07/04/2020 02:39 PM FC005-ElectronicLoad - 1.1 0:15

Actions
194 FC005-ElectronicLoad Anomalie Résolu Normal Noise from MOSFET/Shunt/Feedback in the control 07/14/2020 05:30 PM FC005-ElectronicLoad - 1.1 10:00

Actions
198 FC005-ElectronicLoad Anomalie Résolu Normal PCB silk serigraphy inverted for trig in and out 07/03/2020 06:44 PM FC005-ElectronicLoad - 1.1

Actions
227 FC005-ElectronicLoad Evolution Résolu Normal Protect all connectors against reversed connection 07/23/2020 12:38 AM FC005-ElectronicLoad - 1.1 2:00

Actions
(51-100/274) Per page: 50, 100