openAdd low pass filters on -12V, +12V and +5V
Description
As a final cleaning of the power
Need to evaluate the equivalent resistor for each rail of the circuit and calculate the appropriate capacitor for cutoff at 25Hz-50Hz
100µF/16V and 100µF/10V should probably be enough