Actions
Anomalie #209
openAdd a low pass filter on 24V input
Description
24V volts can be provided by a linear PSU with remaining 100Hz or 50Hz noise or by a switcher with HF noise
Increase C2 to 470µF at least
Actions
Added by François Cerbelle over 4 years ago. Updated over 4 years ago.
Description
24V volts can be provided by a linear PSU with remaining 100Hz or 50Hz noise or by a switcher with HF noise
Increase C2 to 470µF at least
Applied in changeset fc005-electronicload|commit:8e619abf9751.