Actions
Anomalie #204
openRemote Voltage sense stability issue
Description
Replace 1M(R31, R32) and 33K(R34,R35) by 100K and 3K3 respectively and remove C25. This will stabilize the OPA with low sense voltages.
Actions
Added by François Cerbelle over 4 years ago. Updated over 4 years ago.
Description
Replace 1M(R31, R32) and 33K(R34,R35) by 100K and 3K3 respectively and remove C25. This will stabilize the OPA with low sense voltages.
Applied in changeset fc005-electronicload|commit:8e619abf9751.