Project

General

Profile

Actions

Anomalie #204

open

Remote Voltage sense stability issue

Added by François Cerbelle almost 4 years ago. Updated almost 4 years ago.

Status:
Résolu
Priority:
Normal
Assignee:
-
Target version:
Start date:
07/03/2020
Due date:
% Done:

100%

Estimated time:
Spent time:

Description

Replace 1M(R31, R32) and 33K(R34,R35) by 100K and 3K3 respectively and remove C25. This will stabilize the OPA with low sense voltages.

Actions #1

Updated by François Cerbelle almost 4 years ago

  • Status changed from Nouveau to Résolu
Actions #2

Updated by Anonymous almost 4 years ago

  • % Done changed from 0 to 100

Applied in changeset fc005-electronicload|commit:8e619abf9751.